Simpson Strong-Tie® wedge anchor, series: Wedge-All®, a non-bottom-bearing, wedge-style expansion anchor for use in solid concrete or grout-filled masonry. Available in carbon steel with zinc or mechanically galvanized coating, as well as types 303/304 and type 316 stainless steel. Threaded studs are set by tightening the nut to the specified torque. The Wedge-All® is code listed for grout-filled masonry applications.
Features
- Code listed under IBC/IRC for grout-filled CMU per ICC-ESESR-1396
- One-piece, wrap-around clip ensures uniform holding capacity
- Threaded end is chamfered for ease of starting nut
- Available in a wide range of diameters and lengths
- Carbon steel ASTM A563 grade A nut
- The minimum concrete thickness is 1-1/2 times the embedment depth
- The allowable loads are based on a safety factor of 4
- 7/16 in minimum fixture hole
- 30 ft-lb installation torque
- 1560 lb at 2000 psi/2880 lb at 4000 psi ultimate tension loads and 390 lb at 2000 psi, 555 lb at 3000 psi, 720 at 4000 psi allowable tension load for concrete
- 2280 lb at 2000 psi ultimate shear loads and 570 lb at 2000/3000/4000 psi allowable shear load for concrete
- Anchor body material meets minimum 70000 psi tensile strength